ŌNŌ® Retrieval Device

Product Quick Finder

Choose a category or subcategory

Plan Beyond.

The ŌNŌ Retrieval Device is an enabling technology designed to allow clinicians to plan beyond what was previously in reach. The ŌNŌ device is designed to receive, align, compress and remove material from the vascular system. It is compatible with commercially available vascular sheaths, endovascular snares and other graspers.

  • Tear-away sheath allows introduction into any retrieval sheath 12F or greater (maximum 75 cm overall length)
  • Proprietary 35mm basket flare compatible with vessels as small as 10mm
  • Designed to allow unobstructed blood flow when deployed
  • Flexible trackable catheter with 7F compatible lumen or smaller (minimum 100cm length)

Article Code: ONO12-100

Rx only.

Clinical Evidence

1. Elison D et al. First-in-Human Percutaneous Excision of a Failed MitraClip Followed by Transcatheter Mitral Valve Replacement. JACC Cardiovasc Interv. Published online December 20, 2023. doi:10.1016/j.jcin.2023.11.023 https://www.jacc.org/doi/10.1016/j.jcin.2023.11.023

2. Hermann D et al. First-in-Human Percutaneous Removal of Left Atrial Appendage Occlusion Devices With a Novel Retrieval System. JACC Clinical Electrophysiology. Published online March 1, 2024. doi: 10.1016/j.jacep.2024.102328. https://www.jacc.org/doi/10.1016/j.jacep.2024.102328

3. Herron C, Batlivala SP, Shahanavaz S. Right atrial thrombus removal with use of the ŌNŌ retrieval device. Catheter Cardiovasc Interv. 2023;102(6):1105-1108. doi:10.1002/ccd.30877
https://onlinelibrary.wiley.com/doi/10.1002/ccd.30877

4. Karunanandaa A et al. Novel use of the ONO Retrieval System for intracardiac thrombectomy in a high-risk pediatric patient. JSCAI. 2023 May. https://doi.org/10.1016/j.jscai.2023.100976

5. McNamara GPJ et al. Successful removal of a leadless pacemaker from the pulmonary artery via a novel basket retrieval system. HeartRhythm Case Reports. 2023 Apr; 9(4): 215-218.
https://doi.org/10.1016/j.hrcr.2022.12.015

6. Steinberg ZL et al. The simplified extraction of atrial tumor with targeted loop electricity (SEATTLE) procedure. JACC: Case Reports. 2023 Mar. https://www.jacc.org/doi/10.1016/j.jaccas.2023.101758

7. Taylor AC et al. Retrieval of Large Balloon Fragments During Transcatheter Pulmonary Valve Implantation Using a Novel Retrieval System. JACC Case Rep. 2023;26:102058. Published 2023 Oct 18. doi:10.1016/j.jaccas.2023.102058 https://www.jacc.org/doi/abs/10.1016/j.jaccas.2023.102058

Related Documents

Description Document Link
ŌNŌ® Reimbursement Guide
pdf (3.0 MB)
ŌNŌ™ Retrieval Device Brochure
pdf (1.2 MB)
ŌNŌ™ Retrieval Device IFU
pdf (240.1 KB)