G-ARMOR Stent® Portfolio
Choose a category or subcategory
The G-ARMOR Stent®, part of the CP Stent® Family, is the latest large diameter, balloon expandable stent technology.
- Composed of platinum-iridium wire arranged in a unique, laser welded 8 or 10 “zig” pattern and over brazed with 24K gold.
- Available in a Bare and an Expandable ePTFE Covered version in both Pre-Mounted (on a BIB® Catheter) and Unmounted configurations.
- The G-ARMOR Stent® is compatible with introducers ranging from 13 - 18F.
- 12.0mm – 30.0mm stent diameters
- 4.6cm – 6.3cm stent lengths
Additional information
Indications for Use
The G-ARMOR Stent® is indicated for use in the treatment of native and/or recurrent coarctation of the aorta involving a compliant aortic isthmus or first segment of the descending aorta where there is adequate size and patency of at least one femoral artery and balloon angioplasty is contraindicated or predicted to be ineffective.
The G-ARMOR Covered Stent™ is indicated for use in the treatment of native and/or recurrent coarctation of the aorta involving the aortic isthmus or first segment of the descending aorta where there is adequate size and patency of at least one femoral artery associated with one or more of the following: acute or chronic wall injury; nearly atretic descending aorta of 3 mm or less in diameter; a non-compliant stenotic aortic segment found on pre-stent balloon dilation; a genetic or congenital syndrome associated with aortic wall weakening or ascending aortic aneurysm. The G-ARMOR Covered Stent™ is indicated for use in the treatment of right ventricle to pulmonary artery (right ventricular outflow tract) conduit disruptions that are identified during conduit pre-dilatation procedures performed in preparation for transcatheter pulmonary valve replacement.
Caution: Federal (USA) Law restricts this device to sale by or on the order of a physician. Contraindications: Clinical or biological signs of infection. Active endocarditis. Pregnancy. Contraindications (CoA only): Patients too small to allow safe delivery of the stent without compromise to the systemic artery used for delivery. Unfavorable aortic anatomy that does not dilate with high pressure balloon angioplasty. Curved vasculature. Occlusion or obstruction of systemic artery precluding delivery or the stent. Known allergy to aspirin, other antiplatelet agents, or heparin. Contraindications (RVOT only): Patients too small to allow safe delivery of the stent without injury to a systemic vein or to the right side of the heart. Warnings / Precautions: Radiofrequency heating during MRI scans on overlapped, 10 zig G-ARMOR stents has not been evaluated. Excessive force while crimping may weaken welds of the stent. Crimping the 8 zig stent on a balloon catheter smaller than 12mm, and the 10 zig on a balloon catheter smaller than 26mm, may cause damage to the stent. The stent is rigid and may make negotiation through vessels difficult. Warnings / Precautions (CoA only): Coarctation of the aorta involving the aortic isthmus or first segment of the descending aorta should be confirmed by diagnostic imaging. The NuMED G-ARMOR Stent has not been evaluated in patients weighing less than 20kg. As with any type of implant, infection secondary to contamination of the stent may lead to aortitis, or abscess. Over-stretching of the artery may result in rupture or aneurysm formation. Warnings / Precautions (G-ARMOR Covered Stent only): Excessive handling and manipulation of the covering while crimping the stent may cause the covering to tear off of the stent. Crimping the device in the opposite direction of the folds in the covering may cause the covering to catch while inserting into the hemostasis tool and introducer. This could cause the covering to tear off the stent. Pulling the Covered stent back through the introducer and/or hemostasis valve may cause the covering to catch and tear off of the stent. Warnings / Precautions (RVOT only): During the Premarket Approval study the Medtronic Melody valve was used for valve restoration. The safety and effectiveness of the Covered G-ARMOR Stent for pre-stenting of the right ventricular outflow tract (RVOT) landing zone (i.e. prophylaxis or prevention of either RVOT conduit rupture or TPVR fracture; use as a primary RVOT conduit) in preparation of a transcatheter pulmonary valve replacement (TPVR) has not been evaluated. As with any type of implant, infection secondary to contamination of the stent might lead to endocarditis, or abscess formation. The Covered Stent can migrate from the site of implant potentially causing obstruction to pulmonary artery flow. Over-stretching of the RVOT may result in rupture or aneurysm of the RV-PA conduit or the native pulmonary artery. The inflated diameter of the stent should at least equal the diameter of the intended implant site. and/or hemostasis valve may cause the covering to catch and tear off of the stent.
Related Documents
Videos
-
CP Stent® Family of Devices – Mounting Procedure
Articles
Description | Article Code |
---|---|
G ARMOR BARE STENT G10Z46 | 614715 |
G ARMOR BARE STENT G10Z52 | 614716 |
G ARMOR BARE STENT G10Z57 | 614717 |
G ARMOR BARE STENT G10Z63 | 614718 |
G ARMOR BARE STENT G8Z46 | 614719 |
G ARMOR BARE STENT G8Z52 | 614720 |
G ARMOR BARE STENT G8Z57 | 614721 |
G ARMOR BARE STENT G8Z63 | 614722 |
G ARMOR GCM001 4.6CM 12MM 5CM 14F | 614723 |
G ARMOR GCM002 4.6CM 14MM 5CM 14F | 614724 |
G ARMOR GCM003 4.6CM 15MM 5CM 14F | 614725 |
G ARMOR GCM004 4.6CM 16MM 5CM 14F | 614726 |
G ARMOR GCM005 4.6CM 18MM 5CM 14F | 614727 |
G ARMOR GCM006 4.6CM 20MM 5CM 16F | 614728 |
G ARMOR GCM007 4.6CM 22MM 5CM 16F | 614729 |
G ARMOR GCM008 4.6CM 24MM 5CM 16F | 614730 |
G ARMOR GCM009 5.2CM 12MM 5.5CM 14F | 614731 |
G ARMOR GCM010 5.2CM 14MM 5.5CM 14F | 614732 |
G ARMOR GCM011 5.2CM 15MM 5.5CM 14F | 614733 |
G ARMOR GCM012 5.2CM 16MM 5.5CM 14F | 614734 |
G ARMOR GCM013 5.2CM 18MM 5.5CM 14F | 614735 |
G ARMOR GCM014 5.2CM 20MM 5.5CM 16F | 614736 |
G ARMOR GCM015 5.2CM 22MM 5.5CM 16F | 614737 |
G ARMOR GCM016 5.2CM 24MM 5.5CM 16F | 614738 |
G ARMOR GCM017 5.7CM 12MM 6CM 14F | 614739 |
G ARMOR GCM018 5.7CM 14MM 6CM 14F | 614740 |
G ARMOR GCM019 5.7CM 15MM 6CM 14F | 614741 |
G ARMOR GCM020 5.7CM 16MM 6CM 14F | 614742 |
G ARMOR GCM021 5.7CM 18MM 6CM 14F | 614743 |
G ARMOR GCM022 5.7CM 20MM 6CM 16F | 614744 |
G ARMOR GCM023 5.7CM 22MM 6CM 16F | 614745 |
G ARMOR GCM024 5.7CM 24MM 6CM 16F | 614746 |
G ARMOR GCM025 6.3CM 12MM 6.5CM 14F | 614747 |
G ARMOR GCM026 6.3CM 14MM 6.5CM 14F | 614748 |
G ARMOR GCM027 6.3CM 15MM 6.5CM 14F | 614749 |
G ARMOR GCM028 6.3CM 16MM 6.5CM 14F | 614750 |
G ARMOR GCM029 6.3CM 18MM 6.5CM 14F | 614751 |
G ARMOR GCM030 6.3CM 20MM 6.5CM 16F | 614752 |
G ARMOR GCM031 6.3CM 22MM 6.5CM 16F | 614753 |
G ARMOR GCM032 6.3CM 24MM 6.5CM 16F | 614754 |
G ARMOR GCM033 4.6CM 26MM 5CM 16F | 614755 |
G ARMOR GCM034 4.6CM 28MM 5CM 18F | 614756 |
G ARMOR GCM035 4.6CM 30MM 5CM 18F | 614757 |
G ARMOR GCM036 5.2CM 26MM 5.5CM 16F | 614758 |
G ARMOR GCM037 5.2CM 28MM 5.5CM 18F | 614759 |
G ARMOR GCM038 5.2CM 30MM 5.5CM 18F | 614760 |
G ARMOR GCM039 5.7CM 26MM 6CM 16F | 614761 |
G ARMOR GCM040 5.7CM 28MM 6CM 18F | 614762 |
G ARMOR GCM041 5.7CM 30MM 6CM 18F | 614763 |
G ARMOR GCM042 6.3CM 26MM 6.5CM 16F | 614764 |
G ARMOR GCM043 6.3CM 28MM 6.5CM 18F | 614765 |
G ARMOR GCM044 6.3CM 30MM 6.5CM 18F | 614766 |
G ARMOR GM001 4.6CM 12MM 5CM 13F | 614767 |
G ARMOR GM002 4.6CM 14MM 5CM 13F | 614768 |
G ARMOR GM003 4.6CM 15MM 5CM 13F | 614769 |
G ARMOR GM004 4.6CM 16MM 5CM 14F | 614770 |
G ARMOR GM005 4.6CM 18MM 5CM 14F | 614771 |
G ARMOR GM006 4.6CM 20MM 5CM 14F | 614772 |
G ARMOR GM007 4.6CM 22MM 5CM 14F | 614773 |
G ARMOR GM008 4.6CM 24MM 5CM 14F | 614774 |
G ARMOR GM009 5.2CM 12MM 5.5CM 13F | 614775 |
G ARMOR GM010 5.2CM 14MM 5.5CM 13F | 614776 |
G ARMOR GM011 5.2CM 15MM 5.5CM 13F | 614777 |
G ARMOR GM012 5.2CM 16MM 5.5CM 14F | 614778 |
G ARMOR GM013 5.2CM 18MM 5.5CM 14F | 614779 |
G ARMOR GM014 5.2CM 20MM 5.5CM 14F | 614780 |
G ARMOR GM015 5.2CM 22MM 5.5CM 14F | 614781 |
G ARMOR GM016 5.2CM 24MM 5.5CM 14F | 614782 |
G ARMOR GM017 5.7CM 12MM 6CM 13F | 614783 |
G ARMOR GM018 5.7CM 14MM 6CM 13F | 614784 |
G ARMOR GM019 5.7CM 15MM 6CM 13F | 614785 |
G ARMOR GM020 5.7CM 16MM 6CM 14F | 614786 |
G ARMOR GM021 5.7CM 18MM 6CM 14F | 614787 |
G ARMOR GM022 5.7CM 20MM 6CM 14F | 614788 |
G ARMOR GM023 5.7CM 22MM 6CM 14F | 614789 |
G ARMOR GM024 5.7CM 24MM 6CM 14F | 614790 |
G ARMOR GM025 6.3CM 12MM 6.5CM 13F | 614791 |
G ARMOR GM026 6.3CM 14MM 6.5CM 13F | 614792 |
G ARMOR GM027 6.3CM 15MM 6.5CM 13F | 614793 |
G ARMOR GM028 6.3CM 16MM 6.5CM 14F | 614794 |
G ARMOR GM029 6.3CM 18MM 6.5CM 14F | 614795 |
G ARMOR GM030 6.3CM 20MM 6.5CM 14F | 614796 |
G ARMOR GM031 6.3CM 22MM 6.5CM 14F | 614797 |
G ARMOR GM032 6.3CM 24MM 6.5CM 14F | 614798 |
G ARMOR GM033 4.6CM 26MM 5CM 16F | 614799 |
G ARMOR GM034 4.6CM 28MM 5CM 16F | 614800 |
G ARMOR GM035 4.6CM 30MM 5CM 16F | 614801 |
G ARMOR GM036 5.2CM 26MM 5.5CM 16F | 614802 |
G ARMOR GM037 5.2CM 28MM 5.5CM 16F | 614803 |
G ARMOR GM038 5.2CM 30MM 5.5CM 16F | 614804 |
G ARMOR GM039 5.7CM 26MM 6CM 16F | 614805 |
G ARMOR GM040 5.7CM 28MM 6CM 16F | 614806 |
G ARMOR GM041 5.7CM 30MM 6CM 16F | 614807 |
G ARMOR GM042 6.3CM 26MM 6.5CM 16F | 614808 |
G ARMOR GM043 6.3CM 28MM 6.5CM 16F | 614809 |
G ARMOR GM044 6.3CM 30MM 6.5CM 16F | 614810 |
G ARMOR COVERED GC10Z46 | 614811 |
G ARMOR COVERED GC10Z52 | 614812 |
G ARMOR COVERED GC10Z57 | 614813 |
G ARMOR COVERED GC10Z63 | 614814 |
G ARMOR COVERED GC8Z46 | 614815 |
G ARMOR COVERED GC8Z52 | 614816 |
G ARMOR COVERED GC8Z57 | 614817 |
G ARMOR COVERED GC8Z63 | 614818 |